Summary for Test 2024-04-17-104-7

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 994654
DEA: 07313504
EFIS: 0715000090
DIST-CO-RTE-PM07-LA,VEN-1-37.7/62.9,0.0/0.9
Award Date07/20/2023
Closeout DateNot set
Work DescriptionREMOVE AND CONSTRUCT BRIDGE AND CULVERTS.
Location DescriptionLOS ANGELES AND VENTURA COUNTIES AT VARIOUS LOCATIONS FROM 0.4 MILE SOUTH OF TEMESCAL CANYON ROAD TO 0.1 MILE NORTH OF TONGA STREET
QA Service Level1 (Verified on 07/24/2023)

Sample Information

Sample Taken Date04/17/2024 Sample Unique Key104
Date that the sample was received by the laboratory/organization performing the testing04/18/2024 Sample typeQuality Control
A brief description of the sample4x8 cylinders The quantity of what the sample constitutes26
From where was the sample collectedJob Site First name of sampler or witnessed byBrian
Last name of sampler or witnessed byLovett Title of samplerQC Field Technician
Telephone number of sampler Laboratory sample identificationSL675350CE
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameAssociated Ready Mix
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifier00-0000 Structure name26025 Pacific Coast Highway, Malibu, Ca
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSL675350CE
The truck number from where the sample was collectedLoad 1 The batch plant ticket number from where the sample was collected0
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleSet 1
A detailed description of where the material sample was collected26025 Pacific Coast Highway Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2024-04-17-104
DIME Test ID: 2024-04-17-104-7
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-03-21

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Michael Kaus
Date of test: 04/20/2024
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 30880 lb
Maximum load on cylinder 2: 28310 lb
Maximum load on cylinder 3: 30670 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 3 days
Age of specimen in hours: 72 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength (to nearest 10 psi): 2380 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/21/2025 ✔