Summary for Test 2017-09-19-4-3

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 211777
DEA: 04209504
EFIS: 0412000116
DIST-CO-RTE-PM04-MRN,SON-1-50.2/50.5,0.0/0.2
Award Date01/04/2017
Closeout Date10/21/2019
Work DescriptionREPLACE ESTERO BRIDGE AND REALIGN APPROACHING ROADWAY; Bridge No. 27-0121
Location DescriptionMARIN AND SONOMA COUNTIES NEAR VALLEY FORD FROM 0.4 MILE SOUTH OF ESTERO AMERICANO BRIDGE TO 0.2 MILE NORTH OF ESTERO AMERICANO BRIDGE
QA Service Level1 (Verified on 01/17/2017)

Sample Information

Sample Taken Date09/19/2017 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/20/2017
Sample typeQuality Assurance A brief description of the sampleHeavy Hex Bolt Assys
The quantity of what the sample constitutes162 each lot From where was the sample collectedDistributor
First name of sampler or witnessed byStacey Last name of sampler or witnessed byDavis
Title of samplerQAI Telephone number of sampler5624806984
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameBay Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB362-112-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)5479-01, 5479-02
Heat Number(s)CR10411640, NF14103195 Nut Mfg. Lot Number(s)383614C for both
Washer Mfg. Lot Number(s)0217-445 both Bolt SpecificationASTM A325 Hex
Bolt Length(s)4.5, 5.5 Nut SpecificationASTM F563-07
Washer SpecificationASTM F436-19 FinishHDG
Diameter/Size3/4 for both Bolt Mfg. Lot Number762834, 352808A
Rocap Test Requirement(s)yes Lubricant Requirements(s)yes

Test Details

DIME Sample ID: 2017-09-19-4
DIME Test ID: 2017-09-19-4-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-09-28

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 09/20/2017
UTM: 400KIP
Temperature: 72 F
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11AB362-112-17?\"50833226.12Nut Proof LoadBrian

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point File

Test was verified on 9/21/2017