Summary for Test 2024-11-15-66-4

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1000649
DEA: 061H3404
EFIS: 0625000042
DIST-CO-RTE-PM06-TUL-99-23.49
Award Date09/10/2024
Closeout Date05/09/2025
Work DescriptionBRIDGE REPAIR FOR BR #46 0192
Location DescriptionTulare County along NB SR 99 at Avenue 184 OC, Bridge #46 0192.
QA Service Level1 (Verified on 09/26/2024)

Sample Information

Sample Taken Date11/15/2024 Sample Unique Key66
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/16/2024
Sample typeQuality Assurance A brief description of the sampleConcrete Cylinders
The quantity of what the sample constitutesConcrete Cylinders From where was the sample collectedJob Site
First name of sampler or witnessed byStructures Last name of sampler or witnessed byRep
Title of samplerStructures Rep Telephone number of sampler
Laboratory sample identification54 Linked DIME Sample ID
The fabricator/manufacturer/facility nameNot Given Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number180412
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected215042
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedWheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-11-15-66
DIME Test ID: 2024-11-15-66-4
Testing Lab: CT D06 - Visalia Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-03-07

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Jason Ruiz
Date of test: 12/13/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 80221 lb
Maximum load on cylinder 2: 79320 lb
Maximum load on cylinder 3: 78389 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 6381.9 psi
Compressive strength of cylinder 2: 6310.3 psi
Compressive strength of cylinder 3: 6236.2 psi
Compressive strength (to nearest 10 psi): 6310 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/7/2025