Summary for Test 2025-01-31-28-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 994084 DEA: 060U8804 EFIS: 0616000074 |
|---|---|
| DIST-CO-RTE-PM | 06-TUL-99-26.3/27.6 |
| Award Date | 01/23/2023 |
| Closeout Date | Not set |
| Work Description | CONSTRUCT A NEW INTERCHANGE AT COMMERCIAL AVENUE NOW CALLED INTERNATIONAL AGRI-CENTER WAY |
| Location Description | ON STATE ROUTE 99 |
| QA Service Level | 1 (Verified on 03/13/2023) |
Sample Information
| Sample Taken Date | 01/31/2025 | Sample Unique Key | 28 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 02/18/2025 |
| Sample type | Quality Assurance | A brief description of the sample | #14 Dayton Couplers |
| The quantity of what the sample constitutes | 54 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Tanya | Last name of sampler or witnessed by | S |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Nucor Dayton Superior | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | NUCOR |
| Coupler Manufacturer | Dayton Superior | Intermediate Assembler or Fabricator | |
| Rebar Size | #14 | Coupler Model | D310 Taper Lock |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | 6449 | Rebar Heat Number(s) | 3500036691 |
| Rebar Size 2 | Coupler Unique ID | ST-17-11 |
Test Details
DIME Sample ID: 2025-01-31-28
DIME Test ID: 2025-01-31-28-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2025-02-25
Test Results
Number of Samples: 4
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 02/25/2025
UTM: NA
Halo ID: na
Temperature: 0 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 1 | 14 | 2.25 | 0.013 | 197160 | 87500 | service splice | Kleinfelder |
| 2 | 2 | 1 | 14 | 2.25 | 0000 | 198770 | 88500 | service splice | Kleinfelder |
| 3 | 3 | 1 | 14 | 2.25 | 0000 | 201650 | 89500 | service splice | Kleinfelder |
| 4 | 4 | 1 | 14 | 2.25 | 0000 | 200780 | 89000 | service splice | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/25/2025 ✔