Summary for Test 2024-10-24-69-7
Test performed: AASHTO T48-18Project Information
| Project Identifiers | Project ID: 994857 DEA: 010H6104 EFIS: 0117000241 |
|---|---|
| DIST-CO-RTE-PM | 01-HUM-36-13.5/R36.1 |
| Award Date | 10/31/2023 |
| Closeout Date | 09/25/2026 |
| Work Description | COLD PLANE AND OVERLAY HMA, & REPLACE GUARDRAILS. |
| Location Description | HUMBOLDT COUNTY AT AND NEAR BRIDGEVILLE FROM 3.4 MILES WEST OF GRIZZLY CREEK BRIDGE TO 0.8 MILE EAST OF SOUTH FORK VAN DUZEN RIVER |
| QA Service Level | 1 (Verified on 06/08/2023) |
Sample Information
| Sample Taken Date | 10/24/2024 | Sample Unique Key | 69 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/08/2024 | Sample type | Quality Assurance |
| A brief description of the sample | 1 can PG 58-22 binder | The quantity of what the sample constitutes | 1 can binder |
| From where was the sample collected | Source | First name of sampler or witnessed by | Nick |
| Last name of sampler or witnessed by | Smith | Title of sampler | TET |
| Telephone number of sampler | Laboratory sample identification | 24-232 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Mercer Fraser B | |
| Transportation Laboratory (TL) Number | 707453 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 58-22 |
|---|---|---|---|
| Modified | No | Lot number | |
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number | ||
| HMA Type | Not set | HMA Supplier Mix ID Number | Not set |
Test Details
DIME Sample ID: 2024-10-24-69
DIME Test ID: 2024-10-24-69-7
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Test Release Date: 2025-01-27
Test Results
Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg): Celsius and kilopascals
Input Type: Calculated
Tester's full name: Alexis Vargas-Bastida
Date of test: 12/20/2024
Observed Flash Point: 267 C
Ambient Barometric Pressure: 102 kP
Cleveland Open-Cup Flash Point in Celsius: 267 C
General comments (publicly viewable) (Max 1000 characters): FLASH POINT
Test was verified on 1/27/2025 ✔