Summary for Test 2024-11-18-45-1
Test performed: AASHTO T27-14Project Information
| Project Identifiers | Project ID: 995067 DEA: 11430394 EFIS: 1118000115 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-805-23.9/25.1 |
| Award Date | 11/03/2023 |
| Closeout Date | Not set |
| Work Description | WIDEN FREEWAY, STRUCTURES, CONSTRUCT SIGNS, LANDSCAPE AND ELECTRICAL. |
| Location Description | SAN DIEGO COUNTY IN SAN DIEGO FROM 0.2 MILE NORTH OF ROUTE 805/52 SEPARATION TO 0.3 MILE SOUTH OF NOBEL DRIVE OVERCROSSING |
| QA Service Level | 1 (Verified on 12/19/2023) |
Sample Information
| Sample Taken Date | 11/18/2024 | Sample Unique Key | 45 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/05/2024 |
| Sample type | Quality Assurance | A brief description of the sample | RPSU Aggs |
| The quantity of what the sample constitutes | 3 bags | From where was the sample collected | Source |
| First name of sampler or witnessed by | Derrick | Last name of sampler or witnessed by | McCovy |
| Title of sampler | Telephone number of sampler | 6193722435 | |
| Laboratory sample identification | 1007-RPSU | Linked DIME Sample ID | 2024-11-18-43 |
| The fabricator/manufacturer/facility name | Martin Marietta | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | N/A |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | 23417005SR MM |
Test Details
DIME Sample ID: 2024-11-18-45
DIME Test ID: 2024-11-18-45-1
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2024-12-17
Test Results
What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 12/09/2024
| Cumulative Mass Retained | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 5138.0 grams | ||||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 25.0 grams | 100 % | |||||
| 870.0 grams | 83 % | |||||
| 1910.0 grams | 63 % | |||||
| 3165.0 grams | 38 % | |||||
| 513.2 grams | ||||||
| 176.4 grams | 25 % | |||||
| 301.6 grams | 16 % | |||||
| 382.6 grams | 10 % | |||||
| 442.9 grams | 5 % | |||||
| 479.4 grams | 3 % | |||||
| 491.3 grams | 1.6 % | |||||
| 491.8 grams | ||||||
General comments (publicly viewable) (Max 1000 characters): Does not comply. Tested twice, failed twice
Test was verified on 12/17/2024 ✔