Summary for Test 2024-11-01-58-4
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 1000521 DEA: 010P2604 EFIS: 0124000213 |
|---|---|
| DIST-CO-RTE-PM | 01-MEN-101-59.9 |
| Award Date | 07/01/2024 |
| Closeout Date | Not set |
| Work Description | Bridge Deck Replacement |
| Location Description | Long Valley Creek Bridge |
| QA Service Level | 1 (Verified on 08/14/2024) |
Sample Information
| Sample Taken Date | 11/01/2024 | Sample Unique Key | 58 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 11/26/2024 |
| Sample type | Quality Assurance | A brief description of the sample | #5 Lenton Coupler |
| The quantity of what the sample constitutes | 1290 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Oswaldo | Last name of sampler or witnessed by | Chavez |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CMC Erico | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | CMC |
| Coupler Manufacturer | Erico | Intermediate Assembler or Fabricator | |
| Rebar Size | #5 | Coupler Model | A2 |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | L9952 LA508 | Rebar Heat Number(s) | 4142917 6052300 4142866 4143016 4141949 |
| Rebar Size 2 | Coupler Unique ID | ST-17-01 |
Test Details
DIME Sample ID: 2024-11-01-58
DIME Test ID: 2024-11-01-58-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2024-12-09
Test Results
Number of Samples: 4
Input Type: Calculated
Tester's full name: Alexis Vargas-Bastida
Date of test: 12/06/2024
UTM: NA
Halo ID: 000
Temperature: 000 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1 | LOT 3 | 5 | 0.31 | 0.0021 | 29020 | 93613 | Atlas Technical Consultants | Miguel Baltazar |
| 2 | 2 | LOT 3 | 5 | 0.31 | 000 | 29450 | 95000 | Atlas Technical Consultants | Miguel Baltazar |
| 3 | 3 | LOT 3 | 5 | 0.31 | 000 | 28380 | 91548 | Atlas Technical Consultants | Miguel Baltazar |
| 4 | 4 | LOT 3 | 5 | 0.31 | 000 | 27920 | 90065 | Atlas Technical Consultants | Miguel Baltazar |
General comments (publicly viewable) (Max 1000 characters): Atlas Technical Consultants
Test was verified on 12/9/2024 ✔