Summary for Test 2024-11-01-58-3
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 1000521 DEA: 010P2604 EFIS: 0124000213 |
|---|---|
| DIST-CO-RTE-PM | 01-MEN-101-59.9 |
| Award Date | 07/01/2024 |
| Closeout Date | Not set |
| Work Description | Bridge Deck Replacement |
| Location Description | Long Valley Creek Bridge |
| QA Service Level | 1 (Verified on 08/14/2024) |
Sample Information
| Sample Taken Date | 11/01/2024 | Sample Unique Key | 58 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/26/2024 | Sample type | Quality Assurance |
| A brief description of the sample | #5 Lenton Coupler | The quantity of what the sample constitutes | 1290 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Oswaldo |
| Last name of sampler or witnessed by | Chavez | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | CMC Erico | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | CMC |
| Coupler Manufacturer | Erico | Intermediate Assembler or Fabricator | |
| Rebar Size | #5 | Coupler Model | A2 |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | L9952 LA508 | Rebar Heat Number(s) | 4142917 6052300 4142866 4143016 4141949 |
| Rebar Size 2 | Coupler Unique ID | ST-17-01 |
Test Details
DIME Sample ID: 2024-11-01-58
DIME Test ID: 2024-11-01-58-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2024-12-09
Test Results
Number of Samples: 4
Input Type: Calculated
Tester's full name: Alexis Vargas-Bastida
Date of test: 12/06/2024
UTM: NA
Halo ID: 000
Temperature: 000 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1 | LOT 9 | 5 | 0.31 | 0.007 | 26260 | 84710 | Atlas Technical Consultants | Miguel Baltazar |
| 2 | 2 | LOT 9 | 5 | 0.31 | 000 | 28920 | 93290 | Atlas Technical Consultants | Miguel Baltazar |
| 3 | 3 | LOT 9 | 5 | 0.31 | 000 | 27680 | 89290 | Atlas Technical Consultants | Miguel Baltazar |
| 4 | 4 | LOT 9 | 5 | 0.31 | 000 | 19100 | 61613 | Atlas Technical Consultants | Miguel Baltazar |
General comments (publicly viewable) (Max 1000 characters): Atlas Technical Consultants
Test was verified on 12/9/2024 ✔