Summary for Test 2024-11-07-52-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 995067
DEA: 11430394
EFIS: 1118000115
DIST-CO-RTE-PM11-SD-805-23.9/25.1
Award Date11/03/2023
Closeout DateNot set
Work DescriptionWIDEN FREEWAY, STRUCTURES, CONSTRUCT SIGNS, LANDSCAPE AND ELECTRICAL.
Location DescriptionSAN DIEGO COUNTY IN SAN DIEGO FROM 0.2 MILE NORTH OF ROUTE 805/52 SEPARATION TO 0.3 MILE SOUTH OF NOBEL DRIVE OVERCROSSING
QA Service Level1 (Verified on 12/19/2023)

Sample Information

Sample Taken Date11/07/2024 Sample Unique Key52
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing11/14/2024
Sample typeQuality Assurance A brief description of the sample#8 Lenton Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byDoug Last name of sampler or witnessed byna
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Erico Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerErico Intermediate Assembler or Fabricator
Rebar Size#8 Coupler ModelLenton A2
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)M0099 Rebar Heat Number(s)9004392
Rebar Size 2 Coupler Unique IDST-17-01

Test Details

DIME Sample ID: 2024-11-07-52
DIME Test ID: 2024-11-07-52-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2024-12-06

Test Results


Number of Samples: 4
Input Type: Calculated
Tester's full name: Alexis Vargas-Bastida
Date of test: 12/02/2024
UTM: NA
Temperature: 0000 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11M009980.797363093203Atlas Technical ConsultantsMiguel Baltazar
22M009980.797335092848Atlas Technical ConsultantsMiguel Baltazar
33M009980.797383093456Atlas technical ConsultantsMiguel Baltazar
44M009980.797466094506Atlas Technical ConsultantsMiguel Baltazar

General comments (publicly viewable) (Max 1000 characters): Atlas Technical Consultants

Test was verified on 12/6/2024