Summary for Test 2024-11-07-52-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 995067 DEA: 11430394 EFIS: 1118000115 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-805-23.9/25.1 |
| Award Date | 11/03/2023 |
| Closeout Date | Not set |
| Work Description | WIDEN FREEWAY, STRUCTURES, CONSTRUCT SIGNS, LANDSCAPE AND ELECTRICAL. |
| Location Description | SAN DIEGO COUNTY IN SAN DIEGO FROM 0.2 MILE NORTH OF ROUTE 805/52 SEPARATION TO 0.3 MILE SOUTH OF NOBEL DRIVE OVERCROSSING |
| QA Service Level | 1 (Verified on 12/19/2023) |
Sample Information
| Sample Taken Date | 11/07/2024 | Sample Unique Key | 52 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 11/14/2024 |
| Sample type | Quality Assurance | A brief description of the sample | #8 Lenton Couplers |
| The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Doug | Last name of sampler or witnessed by | na |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CMC Erico | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | CMC |
| Coupler Manufacturer | Erico | Intermediate Assembler or Fabricator | |
| Rebar Size | #8 | Coupler Model | Lenton A2 |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | M0099 | Rebar Heat Number(s) | 9004392 |
| Rebar Size 2 | Coupler Unique ID | ST-17-01 |
Test Details
DIME Sample ID: 2024-11-07-52
DIME Test ID: 2024-11-07-52-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Necking)
Test Release Date: 2024-12-06
Test Results
Necking Test Option: Necking Test Option I
Shape of the Sample: Straight Sample
Input Type: Measured
Tester's full name: Alexis Vargas-Bastida
Date of test: 12/02/2024
Sample 1 Visible Necking?: Yes
Sample 1 Location of Fracture?: Threads
Sample 2 Visible Necking?: Yes
Sample 2 Location of Fracture?: Threads
Sample 3 Visible Necking?: Yes
Sample 3 Location of Fracture?: Threads
Sample 4 Visible Necking?: Yes
Sample 4 Location of Fracture?: Threads
General comments (publicly viewable) (Max 1000 characters): Atlas Technical Consultants
Test was verified on 12/6/2024 ✔