Summary for Test 2024-11-16-22-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 993781
DEA: 07322404
EFIS: 0716000055
DIST-CO-RTE-PM07-LA-134-R12.6,R12.9
Award Date08/03/2022
Closeout Date03/13/2025
Work DescriptionREMOVE BRIDGE RAILING AND PLACE CONCRETE BARRIER.
Location DescriptionLOS ANGELES COUNTY IN PASADENA AT ARROYO SECO BRIDGE AND AT THE ORANGE GROVE BOULEVARD ON-RAMP OVERCROSSING
QA Service Level1 (Verified on 05/11/2022)

Sample Information

Sample Taken Date11/16/2024 Sample Unique Key22
Date that the sample was received by the laboratory/organization performing the testing11/18/2024 Sample typeAcceptance
A brief description of the sample3/4" HMA-A 105793 The quantity of what the sample constitutes750 Tons
From where was the sample collectedManufacturer First name of sampler or witnessed byVictor
Last name of sampler or witnessed byPham Title of samplerTET
Telephone number of sampler Laboratory sample identification24-407
Linked DIME Sample ID The fabricator/manufacturer/facility nameAAA-Irwindale
Transportation Laboratory (TL) Number1116B2 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number105793
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-11-16-22
DIME Test ID: 2024-11-16-22-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-11-21

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Daniel Gomez
Date of test: 11/21/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 4014.6 g
Mass of the specimen and specimen basket assembly prior to ignition: 6076.9 g
Mass of HMA Sample prior to ignition: 2062.3 g
Mass Loss: 104.0 g
Mass of aggregate remaining after ignition: 1958.3 g
Correction Factor (Percent by mass of HMA Specimen): 0.34 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.70 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/21/2024 ✔