Summary for Test 2024-11-14-37-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 1000113
DEA: 060U5004
EFIS: 0615000300
DIST-CO-RTE-PM06-KER-5-10.2/16.0
Award Date08/29/2024
Closeout DateNot set
Work DescriptionINDIVIDUAL SLAB REPLACEMENT (RSC), HMA (TYPE A) AND RHMA (GAP GRADED).
Location DescriptionKERN COUNTY AT AND NEAR WHEELER RIDGE FROM GRAPEVINE UNDERCROSSING TO ROUTE 5/99 SEPARATION
QA Service Level1 (Verified on 02/26/2024)

Sample Information

Sample Taken Date11/14/2024 Sample Unique Key37
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/14/2024
Sample typeAcceptance A brief description of the sample4 RSC beams
The quantity of what the sample constitutesISR(RSC ) for20 cu YD From where was the sample collectedJob Site
First name of sampler or witnessed byNeale Last name of sampler or witnessed byBrown
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSPC Volumetric Mobile Yard Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberG3-24-CTS-376
The truck number from where the sample was collected14 The batch plant ticket number from where the sample was collected14
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBack of Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-11-14-37
DIME Test ID: 2024-11-14-37-1
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2024-11-18

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Kulwinder Rai
Date of test: 11/18/2024
Identification number: 7
Width of specimen: 6 inch
Width of specimen 2: 6 inch
Width of specimen 3: 6 inch
Depth of specimen: 6.125 inch
Depth of specimen 2: 6.0625 inch
Depth of specimen 3: 6.125 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 8110 lb
Maximum load applied 2: 7230 lb
Maximum load applied 3: 6920 lb
Curing history and apparent moisture condition of the specimen: 0
If specimen was capped, ground or if leather shims were used: leather shims were used
Defects in specimen, including numbers of beams discarded during test: 0
Age of specimen: 3 days
Age of specimen in hours: no data
Modulus of rupture: 680 psi
Modulus of rupture 2: 620 psi
Modulus of rupture 3: 580 psi
Modulus of rupture average: 630 psi
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
06-0U5004_37038_241114_07_3Dpdf108.83 KB11/18/20242024-11-14-37-1   Info

Test was verified on 11/18/2024