Summary for Test 2017-08-18-1-2
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 211988 DEA: 081C5104 EFIS: 0812000324 |
---|---|
DIST-CO-RTE-PM | 08-RIV-74-17.4/17.8 |
Award Date | 03/09/2017 |
Closeout Date | 06/23/2021 |
Work Description | CONSTRUCT VEHICLE RINSE FACILITY |
Location Description | RIVERSIDE COUNTY IN AND NEAR LAKE ELSINORE AT THE ELSINORE MAINTENANCE STATION AND FROM DEXTER AVENUE TO CONRAD AVENUE |
QA Service Level | 1 (Verified on 08/08/2017) |
Sample Information
Sample Taken Date | 08/18/2017 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/29/2017 |
Sample type | Quality Assurance | A brief description of the sample | 7/8 x 2-3/4 A325 TC Bolt assy |
The quantity of what the sample constitutes | 50 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Russell | Last name of sampler or witnessed by | Lynch |
Title of sampler | QAI | Telephone number of sampler | (213) 538-8219 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Richardson Steel | Transportation Laboratory (TL) Number | C939703 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L96-131-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 20468400 Bolt 75063667 Nut 41542750 Washer | Nut Mfg. Lot Number(s) | |
Washer Mfg. Lot Number(s) | Bolt Specification | A325 | |
Bolt Length(s) | 2-3/4 | Nut Specification | A563 |
Washer Specification | F436 | Finish | MG |
Diameter/Size | 7/8 | Bolt Mfg. Lot Number | 4440771 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2017-08-18-1
DIME Test ID: 2017-08-18-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-09-07
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/30/2017
UTM: 400KIP
Temperature: 72 F
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1B | L96-131-17 | 7/8\" | 71152 | 316.5 | Nut Proof Load | Brian |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 8/31/2017 ✔