Summary for Test 2013-11-07-10201732-2
Test performed: CTM 206-October 2011Project Information
Project Identifiers | Project ID: 7613 DEA: 071218W4 EFIS: 0700021119 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-29.4/31.6 |
Award Date | 11/29/2012 |
Closeout Date | 07/31/2023 |
Work Description | REALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS. |
Location Description | LOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING |
QA Service Level | 1 (Verified on 10/08/2012) |
Sample Information
Sample Taken Date | 11/07/2013 | Sample Unique Key | 10201732 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/12/2013 |
Sample type | Annual Source Testing | A brief description of the sample | 1x 4 PCC Aggregates |
The quantity of what the sample constitutes | 8 Bags | From where was the sample collected | Source |
First name of sampler or witnessed by | Jeff | Last name of sampler or witnessed by | Pollard |
Title of sampler | Not set | Telephone number of sampler | Not set |
Laboratory sample identification | 3291B | Linked DIME Sample ID | Not set |
The fabricator/manufacturer/facility name | Vulcan Materials Complany - Corona | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0027::CORONA QUARRY |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Not set | The fabricator/manufacturer designation for the sample | Not set |
The plant number | Not set | A detailed description of where the material sample was collected | Stockpile at the plant. |
Where the material sample would have been placed if not sampled | Not set | Primary Aggregate Nominal Size | 1 inch |
The concrete mix design number | Lot number | Not set | |
Sublot number | Not set | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2013-11-07-10201732
DIME Test ID: 2013-11-07-10201732-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 206-October 2011: Method of Test for Specific Gravity and Absorption of Coarse Aggregate
Test Release Date: 2014-02-28
Test Results
How will the aggregate be used?: portland cement
Input Type: Calculated
Tester's full name: Nadar Rashidi
Date of test: 11/22/2013
% Water Absorbed: 0.5 %
Bulk Saturated Surface Dry Specific Gravity: 2.72
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/28/2014 ✔