Summary for Test 2024-10-29-11-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 994084
DEA: 060U8804
EFIS: 0616000074
DIST-CO-RTE-PM06-TUL-99-26.3/27.6
Award Date01/23/2023
Closeout DateNot set
Work DescriptionCONSTRUCT A NEW INTERCHANGE AT COMMERCIAL AVENUE NOW CALLED INTERNATIONAL AGRI-CENTER WAY
Location DescriptionON STATE ROUTE 99
QA Service Level1 (Verified on 03/13/2023)

Sample Information

Sample Taken Date10/29/2024 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/29/2024
Sample typeQuality Control A brief description of the sampleStructure Backfill
The quantity of what the sample constitutes1 Bag From where was the sample collectedJob Site
First name of sampler or witnessed byChris Last name of sampler or witnessed byElias
Title of samplerMaterials Tester Telephone number of sampler
Laboratory sample identification Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameSPCI Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifier00-0000
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Unknown
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedstockpile at jobsite
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-10-29-11
DIME Test ID: 2024-10-29-11-1
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2024-10-30

Test Results


What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: Yes
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Jason Ruiz
Date of test: 10/30/2024
Sieve SizeCumulative Mass RetainedCumulative Percent Passing
10143 grams
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
32.0 grams100 %
60.0 grams99 %
1270.0 grams87 %
2443.0 grams76 %
4925.0 grams51 %
480.1 grams
135.6 grams37 %
221.0 grams28 %
285.1 grams21 %
339.3 grams15 %
374.9 grams11 %
401.4 grams8 %
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
06-0U8804_37000_241029_Struc Backfill Agg Basepdf28.64 KB10/30/20242024-10-29-11-1   Info

Test was verified on 10/30/2024