Summary for Test 2024-07-17-82-2

Test performed: ASTM C109-21

Project Information

Project IdentifiersProject ID: 8801
DEA: AML-CEM
EFIS: AML-CEM
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date07/17/2024 Sample Unique Key82
Date that the sample was received by the laboratory/organization performing the testing07/17/2024 Sample typeAnnual Source Testing
A brief description of the sampleSilica Fume The quantity of what the sample constitutes1 Bucket
From where was the sample collectedSource First name of sampler or witnessed byN/A
Last name of sampler or witnessed byNA Title of sampler
Telephone number of sampler Laboratory sample identificationCM24N411
Linked DIME Sample ID The fabricator/manufacturer/facility nameRED CCMA
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeCementitious BrandRED Industrial Products
MillCCMA Type of Cementitious MaterialSilica Fume

Test Details

DIME Sample ID: 2024-07-17-82
DIME Test ID: 2024-07-17-82-2
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-21: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Test Release Date: 2024-10-11

Test Results


Will control cubes be used per ASTM C311?: yes
Input Type: Measured
Tester's full name: KH
Date of test: 10/11/2024
Age of specimen: 8 days
The amount of flow : 100.00 %
The amount of water used : 48.4 %
Compressive strength of 1st specimen : 5322 psi
Compressive strength of 2nd specimen: 5655 psi
Compressive strength of 3rd specimen : 6134 psi
Average Compressive strength (to nearest 10 psi): 5490 psi
Average Compressive strength (to nearest 10 psi) control group: 4770 psi
Strength Activity Index of Portland Cement per ASTM C109: 115 %
General comments (publicly viewable) (Max 1000 characters): Specimen 3 was eliminated from the average for being outside allowable limits per ASTM C109
Test Graph
Source: Bluehill Data Point File

Source: Bluehill Data Point File

Source: Bluehill Data Point File

Test was verified on 10/11/2024 ✔