Summary for Test 2024-10-04-6-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 1000017
DEA: 042Q7004
EFIS: 0419000040
DIST-CO-RTE-PM04-CC-4-L0.0/R14.3
Award Date04/26/2024
Closeout DateNot set
Work DescriptionREPLACE ASPHALT CONCRETE SURFACING AND INSTALL MGS.
Location DescriptionCONTRA COSTA COUNTY IN HERCULES AND CONCORD FROM SAN PABLO AVENUE TO ROUTE 4/242 SEPARATION
QA Service Level1 (Verified on 01/08/2024)

Sample Information

Sample Taken Date10/04/2024 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/04/2024
Sample typeQuality Assurance A brief description of the samplePCC Beam testing 3 hour test
The quantity of what the sample constitutes250 cy From where was the sample collectedSupplier
First name of sampler or witnessed byDan Last name of sampler or witnessed byRingler
Title of samplerLab Technician Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVanguard mobile plant # 887 Martinez Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberHE4X4BM
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected4752
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedAt job site from the transportation truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-10-04-6
DIME Test ID: 2024-10-04-6-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2024-10-04

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Stress
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: Yes
Input Type: Calculated
Tester's full name: Nicholas Hall
Date of test: 10/04/2024
Identification number: Lab test # 781
Width of specimen: 6 inch
Width of specimen 2: 6 inch
Width of specimen 3: 6 inch
Depth of specimen: 6 inch
Depth of specimen 2: 6 inch
Depth of specimen 3: 6 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum recording: 150 psi
Maximum recording 2: 150 psi
Maximum recording 3: 150 psi
Correction Factor: 150
Correction Factor 2: 150
Correction Factor 3: 150
Curing history and apparent moisture condition of the specimen: 3 hour cure before break
If specimen was capped, ground or if leather shims were used: Shims
Defects in specimen, including numbers of beams discarded during test: 0
Age of specimen: 0 days
Age of specimen in hours: 3 hours
Modulus of rupture: 150 psi
Modulus of rupture 2: 150 psi
Modulus of rupture 3: 150 psi
Modulus of rupture average: 150 psi
General comments (publicly viewable) (Max 1000 characters): Spec min 400 PSI

Test was verified on 10/4/2024