Summary for Test 2024-09-24-32-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1000255 DEA: 081N7504 EFIS: 0823000045 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-138,189-21.4/R37.8,0.0/5.6 |
| Award Date | 06/12/2024 |
| Closeout Date | 12/29/2025 |
| Work Description | SLURRY SEAL, TWO-COMPONENT PAINT TRAFFIC STRIPE, REPLACE AC SURFACING. |
| Location Description | SAN BERNARDINO COUNTY ON ROUTE 138 FROM BOLINGBROKE ROAD TO ROUTE 18 AND ON ROUTE 189 FROM ROUTE 18 TO ROUTE 173 |
| QA Service Level | 1 (Verified on 05/15/2024) |
Sample Information
| Sample Taken Date | 09/24/2024 | Sample Unique Key | 32 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/25/2024 | Sample type | Acceptance |
| A brief description of the sample | 3/4" HMA A SP R15 NO LAS | The quantity of what the sample constitutes | 2 BOXES OF HMA, 1 QT PG64-10, 1 BAG RAP |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Maryanna |
| Last name of sampler or witnessed by | Landaverde | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 0495A-24 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | AAA-Corona | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 105793 | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-09-24-32
DIME Test ID: 2024-09-24-32-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-09-27
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Carlos Lievanos
Date of test: 09/26/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2138.2 g
Mass Loss: 105.7 g
Correction Factor (Percent by mass of HMA Specimen): 0.26 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.13 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.55 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/27/2024 ✔