Summary for Test 2024-08-19-82-3

Test performed: AASHTO T51-22

Project Information

Project IdentifiersProject ID: 994857
DEA: 010H6104
EFIS: 0117000241
DIST-CO-RTE-PM01-HUM-36-13.5/R36.1
Award Date10/31/2023
Closeout Date09/25/2026
Work DescriptionCOLD PLANE AND OVERLAY HMA, & REPLACE GUARDRAILS.
Location DescriptionHUMBOLDT COUNTY AT AND NEAR BRIDGEVILLE FROM 3.4 MILES WEST OF GRIZZLY CREEK BRIDGE TO 0.8 MILE EAST OF SOUTH FORK VAN DUZEN RIVER
QA Service Level1 (Verified on 06/08/2023)

Sample Information

Sample Taken Date08/19/2024 Sample Unique Key82
Date that the sample was received by the laboratory/organization performing the testing09/10/2024 Sample typeProduction Start-Up
A brief description of the sample1 can PG 58-22 binder The quantity of what the sample constitutes1 can binder
From where was the sample collectedSource First name of sampler or witnessed byGeorge
Last name of sampler or witnessed byThorpe Title of samplerMaterials Tester
Telephone number of sampler Laboratory sample identification24-173
Linked DIME Sample ID The fabricator/manufacturer/facility nameMercer Fraser B
Transportation Laboratory (TL) Number876487 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2024-08-19-82
DIME Test ID: 2024-08-19-82-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2024-09-19

Test Results


Is a normal test obtainable?: Yes
Number of replicates tested: One
Input Type: Measured
Tester's full name: Juan Gomez
Date of test: 09/19/2024
Ductility of test #1 (D1): 150 cm
Ductility of sample: 150 cm
General comments (publicly viewable) (Max 1000 characters): DUCT

Test was verified on 9/19/2024 ✔