Summary for Test 2024-09-08-20-3

Test performed: AASHTO T11-5

Project Information

Project IdentifiersProject ID: 994084
DEA: 060U8804
EFIS: 0616000074
DIST-CO-RTE-PM06-TUL-99-26.3/27.6
Award Date01/23/2023
Closeout DateNot set
Work DescriptionCONSTRUCT A NEW INTERCHANGE AT COMMERCIAL AVENUE NOW CALLED INTERNATIONAL AGRI-CENTER WAY
Location DescriptionON STATE ROUTE 99
QA Service Level1 (Verified on 03/13/2023)

Sample Information

Sample Taken Date09/08/2024 Sample Unique Key20
Date that the sample was received by the laboratory/organization performing the testing09/09/2024 Sample typeQuality Assurance
A brief description of the sampleHMA Type A The quantity of what the sample constitutes30 Boxes, 6 Bags, 6 Cans
From where was the sample collectedSource First name of sampler or witnessed byMartika
Last name of sampler or witnessed byHall Title of samplerPlant Inspector
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID2024-09-08-18 The fabricator/manufacturer/facility nameMartin Marietta - Visalia
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-54-0038
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedHMA Plant Cold Feed
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number1
Sublot number1 Aggregate Mix Number

Test Details

DIME Sample ID: 2024-09-08-20
DIME Test ID: 2024-09-08-20-3
Testing Lab: CT D06 - Visalia Field Laboratory
Test Method: AASHTO T11-5: Standard Method of Test for Materials Finer Than 75-μm (No. 200) Sieve in Mineral Aggregates by Washing
Test Release Date: 2024-09-11

Test Results


Input Type: Measured
Tester's full name: Chris Elias
Date of test: 09/09/2024
Which test procedure is being used: Method A
Mass of test sample (before test): 342.4 grams
Mass of test sample (after test): 313.7 grams
Percent of sample passing the #200 sieve (by mass): 8.4 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/11/2024 ✔