Summary for Test 2024-07-17-62-1
Test performed: CONCLP 4-16Project Information
| Project Identifiers | Project ID: 995535 DEA: 120T8704 EFIS: 1222000110 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-5,57-30.3/39.6,10.7/21.8 |
| Award Date | 03/01/2024 |
| Closeout Date | 06/23/2025 |
| Work Description | APPLY METHACRYLATE, POLYESTER CONCRETE, AND REPLACE JOINT SEALS. |
| Location Description | ORANGE COUNTY AT VARIOUS LOCATIONS ON ROUTE 5 FROM ROUTE 5/55 SEPARATION TO EUCLID STREET OVERCROSSING AND ON ROUTE 57 FROM ROUTE 5/57 SEPARATION TO TONNER CANYON ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 01/26/2024) |
Sample Information
| Sample Taken Date | 07/17/2024 | Sample Unique Key | 62 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/17/2024 |
| Sample type | Quality Control | A brief description of the sample | 2 pints 204,CHP,8020,Z-CURE |
| The quantity of what the sample constitutes | 100 Totes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Gilberto | Last name of sampler or witnessed by | Gonzalez |
| Title of sampler | Quality Control Manager | Telephone number of sampler | 7076245467 |
| Laboratory sample identification | 000097KBP | Linked DIME Sample ID | 000097KBP |
| The fabricator/manufacturer/facility name | Kwik Bond Polymers, Benicia | Transportation Laboratory (TL) Number | Sacramento Caltrans lab |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Methacrylate | Mfg. Lot Number(s) | 2470091190 |
|---|---|---|---|
| Batch number | 2470091190 | Mix number | 3836 |
Test Details
DIME Sample ID: 2024-07-17-62
DIME Test ID: 2024-07-17-62-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2024-08-27
Test Results
Input Type: Calculated
Tester's full name: Mariano Pontillas
Date of test: 08/09/2024
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 19.46
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 9
Volatile content (ASTM D 2369) 30% max: 8.10
Flash point (ASTM D 3828) more than 180 deg F: 190
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: 659
Tack free time, 400 minutes max: 376
General comments (publicly viewable) (Max 1000 characters): CTM 551 (PCC-SSD Bond Strength) & ASTM C679 (Tack Free Time) accepted vendor's results.
Test was verified on 8/27/2024 ✔