Summary for Test 2024-07-17-62-1

Test performed: CONCLP 4-16

Project Information

Project IdentifiersProject ID: 995535
DEA: 120T8704
EFIS: 1222000110
DIST-CO-RTE-PM12-ORA-5,57-30.3/39.6,10.7/21.8
Award Date03/01/2024
Closeout Date06/23/2025
Work DescriptionAPPLY METHACRYLATE, POLYESTER CONCRETE, AND REPLACE JOINT SEALS.
Location DescriptionORANGE COUNTY AT VARIOUS LOCATIONS ON ROUTE 5 FROM ROUTE 5/55 SEPARATION TO EUCLID STREET OVERCROSSING AND ON ROUTE 57 FROM ROUTE 5/57 SEPARATION TO TONNER CANYON ROAD UNDERCROSSING
QA Service Level1 (Verified on 01/26/2024)

Sample Information

Sample Taken Date07/17/2024 Sample Unique Key62
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/17/2024
Sample typeQuality Control A brief description of the sample2 pints 204,CHP,8020,Z-CURE
The quantity of what the sample constitutes100 Totes From where was the sample collectedSource
First name of sampler or witnessed byGilberto Last name of sampler or witnessed byGonzalez
Title of samplerQuality Control Manager Telephone number of sampler7076245467
Laboratory sample identification000097KBP Linked DIME Sample ID000097KBP
The fabricator/manufacturer/facility nameKwik Bond Polymers, Benicia Transportation Laboratory (TL) NumberSacramento Caltrans lab
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeMethacrylate Mfg. Lot Number(s)2470091190
Batch number2470091190 Mix number3836

Test Details

DIME Sample ID: 2024-07-17-62
DIME Test ID: 2024-07-17-62-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2024-08-27

Test Results


Input Type: Calculated
Tester's full name: Mariano Pontillas
Date of test: 08/09/2024
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 19.46
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 9
Volatile content (ASTM D 2369) 30% max: 8.10
Flash point (ASTM D 3828) more than 180 deg F: 190
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: 659
Tack free time, 400 minutes max: 376
General comments (publicly viewable) (Max 1000 characters): CTM 551 (PCC-SSD Bond Strength) & ASTM C679 (Tack Free Time) accepted vendor's results.

Test was verified on 8/27/2024