Summary for Test 2024-08-07-100-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 995029 DEA: 010K3104 EFIS: 0120000062 |
|---|---|
| DIST-CO-RTE-PM | 01-MEN-101-30.8/R33.8 |
| Award Date | 09/29/2023 |
| Closeout Date | 09/08/2025 |
| Work Description | Calpella Cable Median Barrier |
| Location Description | MENDOCINO COUNTY NEAR UKIAH FROM ROUTE 101/20 SEPARATION TO 0.1 MILE SOUTH OF UVA DRIVE/NORTH STATE STREET |
| QA Service Level | 1 (Verified on 08/07/2023) |
Sample Information
| Sample Taken Date | 08/07/2024 | Sample Unique Key | 100 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/24/2024 |
| Sample type | Acceptance | A brief description of the sample | 1/2" HMA-A 15% RAP PG 64-16 |
| The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Kenny | Last name of sampler or witnessed by | McHugh |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 24-157 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | BoDean Santa Rosa | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | 1 |
| Sublot number | 6 | HMA Mix Number | 600SPW 16 |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-08-07-100
DIME Test ID: 2024-08-07-100-1
Testing Lab: CT D01 - District 1 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-08-20
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Trav
Date of test: 08/13/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1705.7 g
Mass Loss: 103.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.69 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 5.40 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/20/2024 ✔