Summary for Test 2024-08-13-6-4
Test performed: CTM 217-June 2011Project Information
| Project Identifiers | Project ID: 994109 DEA: 060W1704 EFIS: 0617000103 |
|---|---|
| DIST-CO-RTE-PM | 06-FRE-41-R27.4/R28.5 |
| Award Date | 11/08/2022 |
| Closeout Date | Not set |
| Work Description | REMOVE AC PAVEMENT, WIDEN TRAVEL WAY, AND CONSTRUCT RETAINING WALL. |
| Location Description | FRESNO COUNTY IN FRESNO FROM 0.1 MILE SOUTH OF ASHLAN AVENUE OVERCROSSING TO SHAW AVENUE OVERCROSSING |
| QA Service Level | 1 (Verified on 07/13/2022) |
Sample Information
| Sample Taken Date | 08/13/2024 | Sample Unique Key | 6 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/13/2024 |
| Sample type | Quality Assurance | A brief description of the sample | Concrete Aggregates |
| The quantity of what the sample constitutes | 0-1000 yd3 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Noah | Last name of sampler or witnessed by | Hunt |
| Title of sampler | Senior Materials Tester | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Builders Concrete Ready Mix Plant Sanger | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-20-0016 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Belt cut of Coarse and Fine Aggregate at Source | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-08-13-6
DIME Test ID: 2024-08-13-6-4
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2024-08-18
Test Results
Number of tests: 1
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 08/14/2024
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 4.7
Sand reading (test 1): 4
Sand equivalent (test 1): 86
Sand equivalent before temperature correction: 86
Sand equivalent after temperature correction: 86
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/18/2024 ✔