Summary for Test 2024-07-26-38-1

Test performed: ASTM C1064-17

Project Information

Project IdentifiersProject ID: 209109
DEA: 043G9004
EFIS: 0412000557
COOP: 042513
DIST-CO-RTE-PM04-SON-116,121-46.0/46.7,5.8/R7.4
Award Date07/31/2023
Closeout DateNot set
Work DescriptionMODIFY EXISTING STATE ROUTE 116,121 BONNEAU ROAD INTERSECTION FROM A 4 WAY STOP CONTROLLED INTERSECTION TO A ROUNDABOUT AND SIGNALIZED INTERSECTION.
Location DescriptionSONOMA COUNTY
QA Service Level1 (Verified on 08/15/2022)

Sample Information

Sample Taken Date07/26/2024 Sample Unique Key38
Date that the sample was received by the laboratory/organization performing the testing07/26/2024 Sample typeQuality Assurance
A brief description of the sampleRC and Wing wall The quantity of what the sample constitutes9
From where was the sample collectedJob Site First name of sampler or witnessed byJose
Last name of sampler or witnessed byCalderon Title of samplerASR
Telephone number of sampler9164252912 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameShamrock
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberD20115EA
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected652597
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedcocncrete sample from 5 gallon bucket Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-07-26-38
DIME Test ID: 2024-07-26-38-1
Testing Lab: CT SC - 3672 - Santa Rosa
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Test Release Date: 2024-08-05

Test Results


Input Type: Measured
Tester's full name: Jose Calderon Mares
Date of test: 07/26/2024
Temperature: 81 F
General comments (publicly viewable) (Max 1000 characters): Gauge place 3" min inside the concrete for at least 3 minutes

Test was verified on 8/5/2024 ✔