Summary for Test 2024-07-30-24-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 994084
DEA: 060U8804
EFIS: 0616000074
DIST-CO-RTE-PM06-TUL-99-26.3/27.6
Award Date01/23/2023
Closeout DateNot set
Work DescriptionCONSTRUCT A NEW INTERCHANGE AT COMMERCIAL AVENUE NOW CALLED INTERNATIONAL AGRI-CENTER WAY
Location DescriptionON STATE ROUTE 99
QA Service Level1 (Verified on 03/13/2023)

Sample Information

Sample Taken Date07/30/2024 Sample Unique Key24
Date that the sample was received by the laboratory/organization performing the testing07/31/2024 Sample typeQuality Assurance
A brief description of the sampleDouble Barrel Zap Screwlok The quantity of what the sample constitutesNA
From where was the sample collectedJob Site First name of sampler or witnessed byIsaac
Last name of sampler or witnessed byKaing Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameJob Site
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerBarSplice Intermediate Assembler or Fabricator
Rebar Size#4 Coupler ModelDouble Barrel Zap Screwlok
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)20762, 3214 Rebar Heat Number(s)3500037033
Rebar Size 2 Coupler Unique IDSB-17-02

Test Details

DIME Sample ID: 2024-07-30-24
DIME Test ID: 2024-07-30-24-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2024-07-31

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 07/31/2024
UTM: 400kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12No. 4/13mm100.21758387915Service Spliceaauvinen

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 7/31/2024 ✔