Summary for Test 2024-06-18-74-1

Test performed: CONCLP 4-16

Project Information

Project IdentifiersProject ID: 995535
DEA: 120T8704
EFIS: 1222000110
DIST-CO-RTE-PM12-ORA-5,57-30.3/39.6,10.7/21.8
Award Date03/01/2024
Closeout Date06/23/2025
Work DescriptionAPPLY METHACRYLATE, POLYESTER CONCRETE, AND REPLACE JOINT SEALS.
Location DescriptionORANGE COUNTY AT VARIOUS LOCATIONS ON ROUTE 5 FROM ROUTE 5/55 SEPARATION TO EUCLID STREET OVERCROSSING AND ON ROUTE 57 FROM ROUTE 5/57 SEPARATION TO TONNER CANYON ROAD UNDERCROSSING
QA Service Level1 (Verified on 01/26/2024)

Sample Information

Sample Taken Date06/18/2024 Sample Unique Key74
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/18/2024
Sample typeQuality Control A brief description of the sample2 pints 204,CHP,8020
The quantity of what the sample constitutes100 Totes From where was the sample collectedSource
First name of sampler or witnessed byGilberto Last name of sampler or witnessed byGonzalez
Title of samplerQuality Control Manager Telephone number of sampler7076245467
Laboratory sample identification000078KBP Linked DIME Sample ID000078KBP
The fabricator/manufacturer/facility nameKwik Bond Polymers, Benicia Transportation Laboratory (TL) NumberSacramento Caltrans lab
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeMethacrylate Mfg. Lot Number(s)2460991090
Batch number2460991090 Mix number2460991090

Test Details

DIME Sample ID: 2024-06-18-74
DIME Test ID: 2024-06-18-74-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2024-08-01

Test Results


Input Type: Measured
Tester's full name: Rachael Chavez
Date of test: 07/26/2024
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 19.46 cps
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 1.09
Volatile content (ASTM D 2369) 30% max: 10.4 %
Flash point (ASTM D 3828) more than 180 deg F: 190 F
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: 783.587 psi
Tack free time, 400 minutes max: 385 minutes
General comments (publicly viewable) (Max 1000 characters): Accepted vendor's results.

Test was verified on 8/1/2024