Summary for Test 2024-07-25-6-1
Test performed: CTM 231-March 2013Project Information
Project Identifiers | Project ID: 994084 DEA: 060U8804 EFIS: 0616000074 |
---|---|
DIST-CO-RTE-PM | 06-TUL-99-26.3/27.6 |
Award Date | 01/23/2023 |
Closeout Date | Not set |
Work Description | CONSTRUCT A NEW INTERCHANGE AT COMMERCIAL AVENUE NOW CALLED INTERNATIONAL AGRI-CENTER WAY |
Location Description | ON STATE ROUTE 99 |
QA Service Level | 1 (Verified on 03/13/2023) |
Sample Information
Sample Taken Date | 07/25/2024 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 07/25/2024 |
Sample type | Acceptance | A brief description of the sample | Native |
The quantity of what the sample constitutes | 40 lbs native material | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Chris | Last name of sampler or witnessed by | Elias |
Title of sampler | Materials Tester | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | SPCI | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | CTM 231 test location | |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2024-07-25-6
DIME Test ID: 2024-07-25-6-1
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2024-07-25
Test Results
Method Type:: Standard Count
Number of Tests:: 5
Common Test Maximum Used:: Yes
Input Type: Measured
Tester's full name: chris Elias
Date of test: 07/25/2024
Gage No.: 30695
Test No.: 215
Nuclear By: Chris Elias
Non-Bias Plan No.: 7 odd
Depth: 8
Material No.: no data
Material Type: silty sand mod, BRN
Impact By: Chris Elias
Standard Count Density: 1744 g/cc
Count or Density 1: 1015 g/cc
Count or Density 2: 958 g/cc
Count or Density 3: 1066 g/cc
Count or Density 4: 1176 g/cc
Count or Density 5: 990 g/cc
Standard Count Moisture: 651 g/cc
Moisture Count 1: 184 g/cc
Moisture Count 2: 168 g/cc
Moisture Count 3: 158 g/cc
Moisture Count 4: 157 g/cc
Moisture Count 5: 162 g/cc
Density: 1.99
Moisture: 0.22
Sum of Count or Density: 5205.00 g/cc
Average of Count or Density: 1041.00 g/cc
Sum of Moisture Count: 829.00 g/cc
Average of Moisture Count: 166.00 g/cc
Count Ratio Density: 0.60
Count Ratio Moisture: 0.25
Calculated Percent Relative Compaction: 98.5 %
Reported Percent Relative Compaction: 99 %
General comments (publicly viewable) (Max 1000 characters):
Test File Attachments
File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
---|---|---|---|---|---|
06-0U8804_37039_240725_215 | 221.30 KB | 07/25/2024 | 2024-07-25-6-1 | Info |
Test was verified on 7/25/2024 ✔