Summary for Test 2024-07-09-74-3

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994412
DEA: 06442564
EFIS: 0620000053
COOP: 061774
DIST-CO-RTE-PM06-KER,-46-26.1/30.2
Award Date07/17/2023
Closeout Date05/09/2025
Work DescriptionCONVERT 2-LANE CONVENTIONAL HIGHWAY TO A 4-LANE EXPRESSWAY.
Location DescriptionKERN COUNTY IN AND NEAR LOST HILLS FROM 1.3 MILES WEST OF BROWN MATERIAL ROAD TO 0.2 MILE EAST OF CALIFORNIA AQUEDUCT
QA Service Level1 (Verified on 08/21/2023)

Sample Information

Sample Taken Date07/09/2024 Sample Unique Key74
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/09/2024
Sample typeAcceptance A brief description of the sample3/4 Type A HMA
The quantity of what the sample constitutesL1SL121 From where was the sample collectedSource
First name of sampler or witnessed byPaul Last name of sampler or witnessed byKlinker
Title of samplerPlant Inspector Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Solari Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number121 HMA Mix Number
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-07-09-74
DIME Test ID: 2024-07-09-74-3
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-07-15

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Neale Brown
Date of test: 07/09/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 4238.1 g
Mass of the specimen and specimen basket assembly prior to ignition: 6410.8 g
Mass of HMA Sample prior to ignition: 2172.7 g
Mass Loss: 108.5 g
Mass of aggregate remaining after ignition: 2064.2 g
Correction Factor (Percent by mass of HMA Specimen): 0.56 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 4.43 %
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
06-442564_37037_240709_L1SL121_T308_HMApdf105.12 KB07/15/20242024-07-09-74-3   Info

Test was verified on 7/15/2024