Summary for Test 2024-07-12-15-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 994109 DEA: 060W1704 EFIS: 0617000103 |
|---|---|
| DIST-CO-RTE-PM | 06-FRE-41-R27.4/R28.5 |
| Award Date | 11/08/2022 |
| Closeout Date | 08/31/2026 |
| Work Description | REMOVE AC PAVEMENT, WIDEN TRAVEL WAY, AND CONSTRUCT RETAINING WALL. |
| Location Description | FRESNO COUNTY IN FRESNO FROM 0.1 MILE SOUTH OF ASHLAN AVENUE OVERCROSSING TO SHAW AVENUE OVERCROSSING |
| QA Service Level | 1 (Verified on 07/13/2022) |
Sample Information
| Sample Taken Date | 07/12/2024 | Sample Unique Key | 15 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/12/2024 | Sample type | Acceptance |
| A brief description of the sample | 3/4 HMA-SP Type A | The quantity of what the sample constitutes | 215 TONS |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Tomas |
| Last name of sampler or witnessed by | Silva | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan Ashlan | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 2 | HMA Mix Number | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-07-12-15
DIME Test ID: 2024-07-12-15-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-07-14
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 07/12/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 2875.9 g
Mass of the specimen and specimen basket assembly prior to ignition: 4923.4 g
Mass of HMA Sample prior to ignition: 2047.5 g
Mass Loss: 95.3 g
Mass of aggregate remaining after ignition: 1952.2 g
Correction Factor (Percent by mass of HMA Specimen): -0.14 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.15 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.64 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/14/2024 ✔