Summary for Test 2024-01-10-77-3

Test performed: ASTM C109-21

Project Information

Project IdentifiersProject ID: 8801
DEA: AML-CEM
EFIS: AML-CEM
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date01/10/2024 Sample Unique Key77
Date that the sample was received by the laboratory/organization performing the testing04/08/2024 Sample typeAuthorization
A brief description of the sampleBlended cement (PLC) The quantity of what the sample constitutes1 Bucket
From where was the sample collectedSource First name of sampler or witnessed byna
Last name of sampler or witnessed byna Title of sampler
Telephone number of sampler Laboratory sample identificationCM245405
Linked DIME Sample ID The fabricator/manufacturer/facility nameGCC Pueblo IL (10)
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeCementitious BrandGCC of America
MillPueblo Colorado Type of Cementitious MaterialBlended Cement

Test Details

DIME Sample ID: 2024-01-10-77
DIME Test ID: 2024-01-10-77-3
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-21: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Test Release Date: 2024-07-29

Test Results


Will control cubes be used per ASTM C311?: no
Input Type: Measured
Tester's full name: KH
Date of test: 06/10/2024
Age of specimen: 21 days
The amount of flow : 110.00 %
The amount of water used : 48.4 %
Compressive strength of 1st specimen : 5193 psi
Compressive strength of 2nd specimen: 5635 psi
Compressive strength of 3rd specimen : 6125 psi
Average Compressive strength (to nearest 10 psi): 0 psi
General comments (publicly viewable) (Max 1000 characters): The specimens in this test have exceeded both the 3 cube and 2 cube range limits of ASTM C109. No result can be reported. This is a failure of the testing, not the material.
Test Graph
Source: Bluehill Data Point File

Source: Bluehill Data Point File

Source: Bluehill Data Point File

Test was verified on 7/29/2024 ✔