Summary for Test 2017-06-27-2-4
Test performed: ASME B1.2-83r01Project Information
| Project Identifiers | Project ID: 211004 DEA: 05330784 EFIS: 0512000076 |
|---|---|
| DIST-CO-RTE-PM | 05-SLO-46-46.0/50.2 |
| Award Date | 02/10/2016 |
| Closeout Date | 10/15/2019 |
| Work Description | CONVERT 2-LANE TO 4 LANE EXPRESSWAY. |
| Location Description | NEAR SHANDON FROM 0.2 MILE EAST OF MCMILLIAN CANYON ROAD TO 0.4 MILE WEST OF LUCY BROWN ROAD |
| QA Service Level | 1 (Verified on 01/08/2016) |
Sample Information
| Sample Taken Date | 06/27/2017 | Sample Unique Key | 2 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/27/2017 | Sample type | Verification |
| A brief description of the sample | 7/8 x 16 A449 anchor bolt assembly | The quantity of what the sample constitutes | 3 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | David |
| Last name of sampler or witnessed by | Flygare | Title of sampler | CA METS QA Inspector |
| Telephone number of sampler | 801-669-2984 | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | UIS |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | B76-074-17 |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | none |
|---|---|---|---|
| Heat Number(s) | Bolt 166726, washer 41542750, nut10432280 | Nut Mfg. Lot Number(s) | Decker 16-40-005 |
| Washer Mfg. Lot Number(s) | Prestige D2181 | Bolt Specification | A449 |
| Bolt Length(s) | 16" | Nut Specification | A563-DH |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 7/8 | Bolt Mfg. Lot Number | Rockford 29391 |
| Rocap Test Requirement(s) | none | Lubricant Requirements(s) | none |
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2017-06-27-2
DIME Test ID: 2017-06-27-2-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Test Release Date: 2017-07-19
Test Results
Input Type: Calculated
Tester's full name: Brian Ewing
Date of test: 07/11/2017
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 16-40-005
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: DMC DH
Size: .875 in
Gage Type: Pass
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/12/2017 ✔