Summary for Test 2024-06-13-1-2

Test performed: CTM 523-May 2020

Project Information

Project IdentifiersProject ID: 994109
DEA: 060W1704
EFIS: 0617000103
DIST-CO-RTE-PM06-FRE-41-R27.4/R28.5
Award Date11/08/2022
Closeout DateNot set
Work DescriptionREMOVE AC PAVEMENT, WIDEN TRAVEL WAY, AND CONSTRUCT RETAINING WALL.
Location DescriptionFRESNO COUNTY IN FRESNO FROM 0.1 MILE SOUTH OF ASHLAN AVENUE OVERCROSSING TO SHAW AVENUE OVERCROSSING
QA Service Level1 (Verified on 07/13/2022)

Sample Information

Sample Taken Date06/13/2024 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/13/2024
Sample typeAcceptance A brief description of the sampleConcrete beams
The quantity of what the sample constitutes0-1000 Cy @ 19 Cy From where was the sample collectedJob Site
First name of sampler or witnessed byTomas Last name of sampler or witnessed bySilva
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRNR Construction Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberND15518C
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected1358173
Concrete batch plantBuilders Sanger The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedSTA : 1481+60-1481+78 Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-06-13-1
DIME Test ID: 2024-06-13-1-2
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 523-May 2020: Method of Test for Flexural Strength of Concrete
Test Release Date: 2024-07-11

Test Results


Number of specimens: 3
Unit system used?: US Units
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 07/11/2024
Identification number: Set 1
Width of specimen: 6.0 inch
Width of specimen 2: 6.0 inch
Width of specimen 3: 6.0 inch
Depth of specimen: 6.1 inch
Depth of specimen 2: 6.1 inch
Depth of specimen 3: 6.1 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 9400 lb
Maximum load applied 2: 8000 lb
Maximum load applied 3: 8200 lb
Curing history and apparent moisture condition of the specimen: moist
If specimen was capped, ground or if leather shims were used: leather shims
Defects in specimen: none
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Modulus of rupture: 760 psi
Modulus of rupture 2: 645 psi
Modulus of rupture 3: 660 psi
Modulus of rupture average: 690 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/11/2024