Summary for Test 2024-06-27-73-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994310
DEA: 034F6504
EFIS: 0314000233
DIST-CO-RTE-PM03-YOL-50,80-0.0/2.5,4.1/R11.4
Award Date04/07/2023
Closeout DateNot set
Work DescriptionCRCP, HMA (TYPE A), RDWY EXC, CLASS 2 AB, FIBER OPTIC CABLE SYSTEMS.
Location DescriptionYOLO COUNTY IN AND NEAR WEST SACRAMENTO ON ROUTE 80 FROM 1.7 MILES EAST OF MACE BOULEVARD OVERCROSSING TO SACRAMENTO RIVER BRIDGE AND OVERHEAD (BRYTE BEND) AND ON ROUTE 50 FROM ROUTE 80 JUNCTION TO JEFFERSON BOULEVARD UNDERCROSSING
QA Service Level1 (Verified on 10/04/2022)

Sample Information

Sample Taken Date06/27/2024 Sample Unique Key73
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/03/2024
Sample typeQuality Assurance A brief description of the sample2 Boxes
The quantity of what the sample constitutes3/4" RHMA-G From where was the sample collectedSource
First name of sampler or witnessed byDustin Last name of sampler or witnessed byKliethermes
Title of sampler Telephone number of sampler
Laboratory sample identificationDaily 24-084 Linked DIME Sample ID2024-06-27-37
The fabricator/manufacturer/facility nameTeichert Perkins Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number2
Sublot number5 HMA Mix Number

Test Details

DIME Sample ID: 2024-06-27-73
DIME Test ID: 2024-06-27-73-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-07-10

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 07/09/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2172.9 g
Mass Loss: 173.2 g
Correction Factor (Percent by mass of HMA Specimen): 0.32 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.68 %
General comments (publicly viewable) (Max 1000 characters): L1 OBC 7.5

Test was verified on 7/10/2024