Summary for Test 2024-02-06-20-3
Test performed: ASTM C109-21Project Information
| Project Identifiers | Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for Cementitious Materials for use in Concrete Authorized Material List (AML) |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 02/06/2024 | Sample Unique Key | 20 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 02/06/2024 | Sample type | Annual Source Testing |
| A brief description of the sample | Natural Pozzolan | The quantity of what the sample constitutes | 1 Bucket |
| From where was the sample collected | Source | First name of sampler or witnessed by | N/A |
| Last name of sampler or witnessed by | NA | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | CM235383 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Nevada Fernley Natural Pozzolan | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Cementitious | Brand | Nevada Cement |
|---|---|---|---|
| Mill | Fernley | Type of Cementitious Material | Class F or N Flyash |
Test Details
DIME Sample ID: 2024-02-06-20
DIME Test ID: 2024-02-06-20-3
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-21: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Test Release Date: 2024-07-17
Test Results
Will control cubes be used per ASTM C311?: yes
Input Type: Measured
Tester's full name: AV
Date of test: 07/09/2024
Age of specimen: 28 days
The amount of flow : 106.00 %
The amount of water used : 48.4 %
Compressive strength of 1st specimen : 5500 psi
Compressive strength of 2nd specimen: 5075 psi
Compressive strength of 3rd specimen : 5469 psi
Average Compressive strength (to nearest 10 psi): 5350 psi
Average Compressive strength (to nearest 10 psi) control group: 5510 psi
Strength Activity Index of Portland Cement per ASTM C109: 97 %
General comments (publicly viewable) (Max 1000 characters): 28 day
Test Graph
Source: Bluehill Data Point FileSource: Bluehill Data Point File
Source: Bluehill Data Point File
Test was verified on 7/17/2024 ✔
