Summary for Test 2017-06-15-4-1

Test performed: CONCLP 3-16

Project Information

Project IdentifiersProject ID: 7613
DEA: 071218W4
EFIS: 0700021119
DIST-CO-RTE-PM07-LA-5-29.4/31.6
Award Date11/29/2012
Closeout Date07/31/2023
Work DescriptionREALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS.
Location DescriptionLOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING
QA Service Level1 (Verified on 10/08/2012)

Sample Information

Sample Taken Date06/15/2017 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing06/15/2017 Sample typeQuality Control
A brief description of the sample1 gallon can The quantity of what the sample constitutes2 tankers
From where was the sample collectedSource First name of sampler or witnessed byChris
Last name of sampler or witnessed byNunes Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameKwik bond and Reichhold
Transportation Laboratory (TL) NumberSacramento Caltrans lab Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypePolyester Mfg. Lot Number(s)1057687
Batch Number1057687 Mix number1057687

Test Details

DIME Sample ID: 2017-06-15-4
DIME Test ID: 2017-06-15-4-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 3-16: Polyester Resin
Test Release Date: 2017-07-17

Test Results


Input Type: Calculated
Tester's full name: Mike Mullins
Date of test: 07/10/2017
Viscosity ASTM D 2196, RVT, No. 1 spindle 75 to 200 cps @ 20 RPM, 77°F: 97 cps
Specific gravity ASTM D 1475 1.05 to 1.10 @ 77°F: 1.07
Conditioning (18/25/50 + 5/70) Elogation ASTM D 638, minimum 35%: 53.9 %
Tensile Strength ASTM D 638 Type 1 @ 0.45 in/min, minimum 2500 psi: 2676 psi
Styrene ASTM D 2369 40% to 50 %: 46 %
PCC - SSD bond strength CTM 551 500 psi minimun @ 24 hours: 602 psi
Static Volatile Emissions, SCAQMD 309-91, maximum loss 1.0 grams: 0.6 grams
General comments (publicly viewable) (Max 1000 characters): accepted suppliers bond Q.C. results our press is down

Test was verified on 7/10/2017