Summary for Test 2024-06-07-37-3

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 995061
DEA: 081J9104
EFIS: 0818000135
DIST-CO-RTE-PM08-RIV,SBD-10,15,60,62,91,etc.-Var
Award Date10/11/2023
Closeout Date06/09/2025
Work DescriptionMODIFYING CMS SYSTEMS, SIGN FOUNDATION AND SIGN STRUCTURE.
Location DescriptionRIVERSIDE AND SAN BERNARDINO COUNTIES AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 08/15/2023)

Sample Information

Sample Taken Date06/07/2024 Sample Unique Key37
Date that the sample was received by the laboratory/organization performing the testing06/10/2024 Sample typeQuality Assurance
A brief description of the sample4x8 The quantity of what the sample constitutes11
From where was the sample collectedJob Site First name of sampler or witnessed byNafisat
Last name of sampler or witnessed byA Title of samplerASR
Telephone number of sampler Laboratory sample identification1067-07J
Linked DIME Sample ID The fabricator/manufacturer/facility nameCemex
Transportation Laboratory (TL) Number1067-07J Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1610974
The truck number from where the sample was collected10076263 The batch plant ticket number from where the sample was collected42859109
Concrete batch plantCEMEX FONTANA The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedUPGRADE CMS FOOTINGS LOCATION 6 Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-06-07-37
DIME Test ID: 2024-06-07-37-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2024-07-05

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Jose Guzman
Date of test: 07/05/2024
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.01 in
Maximum load on cylinder 1: 78050 lb
Maximum load on cylinder 2: 75580 lb
Maximum load on cylinder 3: 77180 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.63 in^2
Compressive strength of cylinder 1: 6209.2 psi
Compressive strength of cylinder 2: 6012.7 psi
Compressive strength of cylinder 3: 6110.8 psi
Compressive strength (to nearest 10 psi): 6110 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/5/2024 ✔