Summary for Test 2024-06-13-96-2

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 995061
DEA: 081J9104
EFIS: 0818000135
DIST-CO-RTE-PM08-RIV,SBD-10,15,60,62,91,etc.-Var
Award Date10/11/2023
Closeout Date06/09/2025
Work DescriptionMODIFYING CMS SYSTEMS, SIGN FOUNDATION AND SIGN STRUCTURE.
Location DescriptionRIVERSIDE AND SAN BERNARDINO COUNTIES AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 08/15/2023)

Sample Information

Sample Taken Date06/13/2024 Sample Unique Key96
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/13/2024
Sample typeAcceptance A brief description of the sample1" PCC
The quantity of what the sample constitutes20 CY From where was the sample collectedManufacturer
First name of sampler or witnessed byMohammed Last name of sampler or witnessed byHaque
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCemex - Fontana Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0040
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut at Cemex Fontana Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number1610974 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-06-13-96
DIME Test ID: 2024-06-13-96-2
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2024-07-02

Test Results


What size aggregate is being tested?: 0.375 in x No. 8 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Mohammed Haque
Date of test: 06/14/2024
Sieve SizeCumulative Percent Passing
100 %
93 %
18 %
4 %
General comments (publicly viewable) (Max 1000 characters): 3/8" x No. 8

Test was verified on 7/2/2024