Summary for Test 2024-05-29-91-4
Test performed: CTM 217-June 2011Project Information
| Project Identifiers | Project ID: 995061 DEA: 081J9104 EFIS: 0818000135 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV,SBD-10,15,60,62,91,etc.-Var |
| Award Date | 10/11/2023 |
| Closeout Date | 06/09/2025 |
| Work Description | MODIFYING CMS SYSTEMS, SIGN FOUNDATION AND SIGN STRUCTURE. |
| Location Description | RIVERSIDE AND SAN BERNARDINO COUNTIES AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 08/15/2023) |
Sample Information
| Sample Taken Date | 05/29/2024 | Sample Unique Key | 91 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/29/2024 |
| Sample type | Acceptance | A brief description of the sample | 1" PCC |
| The quantity of what the sample constitutes | 20 CY | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Kalpesh | Last name of sampler or witnessed by | Patel |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Cemex - Fontana | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-36-0040 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Belt Cut at Cemex Fontana Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
| The concrete mix design number | 1610974 | Lot number | |
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-05-29-91
DIME Test ID: 2024-05-29-91-4
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2024-07-02
Test Results
Number of tests: 2
Input Type: Calculated
Tester's full name: MaryAnna Landaverde
Date of test: 05/30/2024
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 5
Sand reading (test 1): 4.2
Clay reading (test 2): 4.8
Sand reading (test 2): 4.1
Sand equivalent (test 1): 84
Sand equivalent (test 2): 86
Sand equivalent before temperature correction: 85
Sand equivalent after temperature correction: 85
General comments (publicly viewable) (Max 1000 characters): WCS
Test was verified on 7/2/2024 ✔