Summary for Test 2017-06-29-5-3
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 208945 DEA: 07288604 EFIS: 0700021080 COOP: 074663 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-710-6.0-9.4 |
| Award Date | 09/02/2011 |
| Closeout Date | Not set |
| Work Description | Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing. |
| Location Description | Port of Long Beach (District 7) |
| QA Service Level | 1 (Verified on 06/03/2013) |
Sample Information
| Sample Taken Date | 06/29/2017 | Sample Unique Key | 5 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 07/03/2017 |
| Sample type | Independent Assurance | A brief description of the sample | Hoops |
| The quantity of what the sample constitutes | 4 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Johnston |
| Title of sampler | IQA | Telephone number of sampler | 9165247768 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CMC Rebar | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L5313917 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 4063378 |
| Hoop Manufacturer Lot Number(s) | 18 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | 8 |
| Diameter of Hoop | 8'-6" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | CMC Rebar |
| Welding Company | CMC Rebar (Etiwanda) | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2017-06-29-5
DIME Test ID: 2017-06-29-5-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-07-13
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 07/06/2017
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 3 | 18 | #8/25mm | 0.79 | 77990 | 98720 | Bar Broke | Fred |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 7/6/2017 ✔