Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2017-06-29-5

Project Information

Project IdentifiersProject ID: 208945
DEA: 07288604
EFIS: 0700021080
COOP: 074663
DIST-CO-RTE-PM07-LA-710-6.0-9.4
Award Date09/02/2011
Closeout DateNot set
Work DescriptionGerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location DescriptionPort of Long Beach (District 7)
QA Service Level1 (Verified on 06/03/2013)

Sample Information

Sample Taken Date06/29/2017 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing07/03/2017
Sample typeIndependent Assurance A brief description of the sampleHoops
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byGreg Last name of sampler or witnessed byJohnston
Title of samplerIQA Telephone number of sampler9165247768
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Rebar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL5313917 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)4063378
Hoop Manufacturer Lot Number(s)18 Material Standard CodeASTM A706
Material Grade60 Rebar Size8
Diameter of Hoop8'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Rebar
Welding CompanyCMC Rebar (Etiwanda) Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-06-29-5-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory07/06/2017Fred
Yes
07/13/2017Bar Broke; OK Necking
2017-06-29-5-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory07/06/2017Fred
Yes
07/13/2017Bar Broke; OK Necking
2017-06-29-5-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory07/06/2017Fred
Yes
07/13/2017Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-06-29-5-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-06-29-5-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-06-29-5-3 CTM 670-December 2013 (Verified)