Summary for Test 2024-06-25-61-2
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 994116 DEA: 010J4104 EFIS: 0119000025 |
|---|---|
| DIST-CO-RTE-PM | 01-HUM-299-30.7/33.4 |
| Award Date | 11/23/2022 |
| Closeout Date | Not set |
| Work Description | Project Name: HUM-299 Curve Improvement |
| Location Description | HUMBOLDT COUNTY NEAR WILLOW CREEK FROM 0.1 MILE EAST OF CEDAR CREEK ROAD TO 0.1 MILE EAST OF EAST FORK WILLOW CREEK BRIDGE |
| QA Service Level | 1 (Verified on 07/29/2022) |
Sample Information
| Sample Taken Date | 06/25/2024 | Sample Unique Key | 61 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/25/2024 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4" HMA-A 15% RAP PG 64-16 | The quantity of what the sample constitutes | 750 Tons |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | George |
| Last name of sampler or witnessed by | Thorpe | Title of sampler | Consultant tester |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Kernen | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-06-25-61
DIME Test ID: 2024-06-25-61-2
Testing Lab: CT D01 - District 1 Materials Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2024-06-28
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Calculated
Tester's full name: Tom Brown
Date of test: 06/27/2024
Specific Gravity for Sample 1: 2.494
Theoretical maximum density at 25°C (77°F): 2486.8 kg/m^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/28/2024 ✔