Summary for Test 2024-05-28-22-2

Test performed: AASHTO T59-22

Project Information

Project IdentifiersProject ID: 994245
DEA: 051H4304
EFIS: 0516000073
DIST-CO-RTE-PM05-SB-101-21.4/21.9
Award Date03/02/2023
Closeout DateNot set
Work DescriptionSan Jose Creek Bridge replacement
Location DescriptionSANTA BARBARA COUNTY IN GOLETA FROM ROUTE 101/217 SEPARATION TO 0.3 MILE NORTH OF SAN JOSE CREEK BRIDGE
QA Service Level1 (Verified on 09/19/2022)

Sample Information

Sample Taken Date05/28/2024 Sample Unique Key22
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/31/2024
Sample typeAcceptance A brief description of the sampleSS-1H
The quantity of what the sample constitutes2 JUGS OF EMULSION From where was the sample collectedJob Site
First name of sampler or witnessed byG Last name of sampler or witnessed byADKINS
Title of samplerTE Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namePavement Coatings Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphaltic Emulsion Emulsion GradeSS-1h
Lot NumberNot set Sub LotNot set
Dilution Percentage RateNot set

Test Details

DIME Sample ID: 2024-05-28-22
DIME Test ID: 2024-05-28-22-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Test Release Date: 2024-06-03

Test Results


How many beakers will be used to conduct the test?: 2
Input Type: Measured
Tester's full name: Raul Cardenas
Date of test: 06/03/2024
Beaker 1 Mass of beaker, rod, screen (if used), and residue: 151.3 g
Beaker 1 Tare mass of the beaker, rod, and screen (if used): 121.9 g
Beaker 2 Mass of beaker, rod, screen (if used), and residue: 151.6 g
Beaker 2 Tare mass of the beaker, rod, and screen (if used): 122.0 g
Beaker 1 Residue: 58.8 %
Beaker 2 Residue: 59.2 %
Percentage of residue: 59 %
General comments (publicly viewable) (Max 1000 characters): EVAP

Test was verified on 6/3/2024