Summary for Test 2017-06-21-1-15

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 211718
DEA: 120H5304
EFIS: 1213000147
DIST-CO-RTE-PM12-ORA-5-6.8,22.8
Award Date11/10/2016
Closeout Date08/27/2018
Work DescriptionBRIDGE RAIL UPGRADE AND DECK REPLACEMENT
Location DescriptionORANGE COUNTY IN SAN JUAN CAPISTRANO AND IRVINE AT NORTHBOUND CAMINO LAS RAMBLAS LOOP ON RAMP AND NEAR BEE CANYON CREEK
QA Service Level1 (Verified on 01/18/2017)

Sample Information

Sample Taken Date06/21/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/26/2017
Sample typeQuality Assurance A brief description of the sampleA325 MG
The quantity of what the sample constitutes16 and 36 From where was the sample collectedFabricator
First name of sampler or witnessed byGreg Last name of sampler or witnessed byJohnston
Title of samplerCA METS QA Inspector Telephone number of sampler9165247768
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameStructural and Steel Products Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)170613B 170613A
Heat Number(s)NF15102338 CR10356300 Nut Mfg. Lot Number(s)38621366009A 3A
Washer Mfg. Lot Number(s)21445870 512224 Bolt SpecificationA325
Bolt Length(s)2 1/2" 2 1/4" Nut SpecificationA563
Washer SpecificationF436 FinishMG
Diameter/Size3/4 5/8 Bolt Mfg. Lot NumberDL16105190 NF15101077
Rocap Test Requirement(s)Yes Lubricant Requirements(s)Yes

Test Details

DIME Sample ID: 2017-06-21-1
DIME Test ID: 2017-06-21-1-15
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-07-05

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 06/27/2017
UTM: 400KIP
Temperature: 71 F
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
12AL53-135-175/8\"34575153.8Nut Proof LoadBrian

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point File

Test was verified on 6/28/2017