Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2017-06-21-1
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 211718 DEA: 120H5304 EFIS: 1213000147 |
---|---|
DIST-CO-RTE-PM | 12-ORA-5-6.8,22.8 |
Award Date | 11/10/2016 |
Closeout Date | 08/27/2018 |
Work Description | BRIDGE RAIL UPGRADE AND DECK REPLACEMENT |
Location Description | ORANGE COUNTY IN SAN JUAN CAPISTRANO AND IRVINE AT NORTHBOUND CAMINO LAS RAMBLAS LOOP ON RAMP AND NEAR BEE CANYON CREEK |
QA Service Level | 1 (Verified on 01/18/2017) |
Sample Information
Sample Taken Date | 06/21/2017 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/26/2017 |
Sample type | Quality Assurance | A brief description of the sample | A325 MG |
The quantity of what the sample constitutes | 16 and 36 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Johnston |
Title of sampler | CA METS QA Inspector | Telephone number of sampler | 9165247768 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Structural and Steel Products | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 170613B 170613A |
---|---|---|---|
Heat Number(s) | NF15102338 CR10356300 | Nut Mfg. Lot Number(s) | 38621366009A 3A |
Washer Mfg. Lot Number(s) | 21445870 512224 | Bolt Specification | A325 |
Bolt Length(s) | 2 1/2" 2 1/4" | Nut Specification | A563 |
Washer Specification | F436 | Finish | MG |
Diameter/Size | 3/4 5/8 | Bolt Mfg. Lot Number | DL16105190 NF15101077 |
Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | Yes |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2017-06-21-1-1 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-06-21-1-2 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-21-1-4 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-21-1-5 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-21-1-6 ASTM E18-15 (Verified)
DIME Test ID: 2017-06-21-1-7 ASTM E18-15 (Verified)
DIME Test ID: 2017-06-21-1-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-06-21-1-9 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-21-1-10 ASTM E18-15 (Verified)
DIME Test ID: 2017-06-21-1-11 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-21-1-12 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-21-1-13 ASTM E18-15 (Verified)
DIME Test ID: 2017-06-21-1-14 ASTM F606-14a (Verified)
DIME Test ID: 2017-06-21-1-15 ASTM F606-14a (Verified)