Summary for Test 2017-06-19-2-1
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 210549 DEA: 11409304 EFIS: 1112000070 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-75,15,163-R21.0/R21.6 |
| Award Date | 09/01/2015 |
| Closeout Date | 07/05/2019 |
| Work Description | CLEAN AND PAINT THE CORONADO BRIDGE AND BUILD TRAVELER SYSTEMS. |
| Location Description | SAN DIEGO COUNTY IN SAN DIEGO FROM 0.9 NORTH TO 1.5 MILES NORTH OF GLORIETTA BOULEVARD |
| QA Service Level | 1 (Verified on 09/22/2015) |
Sample Information
| Sample Taken Date | 06/19/2017 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/21/2017 |
| Sample type | Quality Assurance | A brief description of the sample | A325 HDG Rocap Assembiy |
| The quantity of what the sample constitutes | 127 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Churchill |
| Title of sampler | QA Inspector | Telephone number of sampler | 510-693-3545 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Cordova Bolt | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 304-17-02 |
|---|---|---|---|
| Heat Number(s) | DL16101276 Bolt, NF14102478 Nut, 164291 Washer | Nut Mfg. Lot Number(s) | 349781D |
| Washer Mfg. Lot Number(s) | 0716-309 | Bolt Specification | A325 |
| Bolt Length(s) | 1-3/4" | Nut Specification | A563 DH |
| Washer Specification | F436 | Finish | Hot Dipped Galvanized |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | 378487A |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2017-06-19-2
DIME Test ID: 2017-06-19-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-07-03
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 06/23/2017
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | 3497810 | 1/2\" | 21582 | 96 | Nut Proof Load | Brian |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 6/26/2017 ✔