Summary for Test 2024-04-15-84-1
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 994944 DEA: 081J2304 EFIS: 0818000002 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-60-R1.0/12.0 |
| Award Date | 09/20/2023 |
| Closeout Date | 04/28/2025 |
| Work Description | RAMP METERING SYSTEM, HMA (TYPE A), RDWY EXC, MOD SIGNAL & LTG SYSTEMS |
| Location Description | RIVERSIDE COUNTY IN AND NEAR JURUPA VALLEY AND RIVERSIDE AT VARIOUS LOCATIONS FROM WINEVILLE ROAD UNDERCROSSING TO 0.2 MILE WEST OF ROUTE 60/91 SEPARATION |
| QA Service Level | 1 (Verified on 07/28/2023) |
Sample Information
| Sample Taken Date | 04/15/2024 | Sample Unique Key | 84 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/16/2024 |
| Sample type | Quality Control | A brief description of the sample | structural concrete |
| The quantity of what the sample constitutes | 2 cylinders | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | John | Last name of sampler or witnessed by | Byington |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Cemex Fontana | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 1610974 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 31164188 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | DS Junction Structure | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-04-15-84
DIME Test ID: 2024-04-15-84-1
Testing Lab: Sequoia Consultants
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-05-17
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Gavin Hernandez
Date of test: 05/13/2024
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 161360 lb
Maximum load on cylinder 2: 160400 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength (to nearest 10 psi): 5670 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/17/2024 ✔