Summary for Test 2017-06-02-3-4
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 211162 DEA: 044G4504 EFIS: 0412000477 |
---|---|
DIST-CO-RTE-PM | 04-SOL-780-7.07 |
Award Date | 02/01/2017 |
Closeout Date | 11/15/2019 |
Work Description | REPLACE BRIDGE TO PROVIDE STANDARD VERTICAL CLEARANCE |
Location Description | LAUREL STREET OC |
QA Service Level | 1 (Verified on 05/20/2016) |
Sample Information
Sample Taken Date | 06/02/2017 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/05/2017 |
Sample type | Quality Assurance | A brief description of the sample | concrete cylinders |
The quantity of what the sample constitutes | cylinders | From where was the sample collected | Job Site |
First name of sampler or witnessed by | mike | Last name of sampler or witnessed by | mullins |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Translab | Transportation Laboratory (TL) Number | Batch 2 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
Structure name | Unknown |
Material Information
Material Type | Concrete | The concrete mix design number | js1000 |
---|---|---|---|
The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | on site mix |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | Mixed on Site | Where the material sample would have been placed if not sampled | Unknown |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2017-06-02-3
DIME Test ID: 2017-06-02-3-4
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2017-06-16
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: MM
Date of test: 06/16/2017
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 3.03 in
Average diameter of cylinder 2: 3.04 in
Average diameter of cylinder 3: 3.03 in
Maximum load on cylinder 1: 143122 lb
Maximum load on cylinder 2: 137977 lb
Maximum load on cylinder 3: 153668 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Correction factor for cylinder 3: no data
Age of specimen: 14 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 7.21 in^2
Cross sectional area of cylinder 2: 7.26 in^2
Cross sectional area of cylinder 3: 7.21 in^2
Compressive strength of cylinder 1: 19850.5 psi
Compressive strength of cylinder 2: 19005.1 psi
Compressive strength of cylinder 3: 21313.2 psi
Compressive strength (to nearest 10 psi): 20060 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Cylinder Code 1 of 3
Source: Partner Data Point File
Test graph for Cylinder Code 2 of 3
Source: Partner Data Point File
Test graph for Cylinder Code 3 of 3
Test was verified on 6/16/2017 ✔