Summary for Test 2024-04-28-6-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 994730 DEA: 040Y1904 EFIS: 0422000255 |
|---|---|
| DIST-CO-RTE-PM | 04-SOL-37-R0.0/R7.4 |
| Award Date | 06/27/2023 |
| Closeout Date | 11/27/2024 |
| Work Description | COLD PLANE ASPHALT CONCRETE PAVEMENT AND OVERLAY WITH RHMA-G. |
| Location Description | SOLANO COUNTY IN AND NEAR VALLEJO FROM SONOMA COUNTY LINE TO NAPA RIVER BRIDGE |
| QA Service Level | 1 (Verified on 05/10/2023) |
Sample Information
| Sample Taken Date | 04/28/2024 | Sample Unique Key | 6 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 05/01/2024 | Sample type | Quality Assurance |
| A brief description of the sample | 1/2-INCH RHMA-G | The quantity of what the sample constitutes | 1794 Grams |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Nick |
| Last name of sampler or witnessed by | HALL | Title of sampler | |
| Telephone number of sampler | 7072999133 | Laboratory sample identification | Con_24_261 |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan Vallejo Drier Drum Plant | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | 1 |
| Sublot number | 11 | HMA Mix Number | 326122 |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-04-28-6
DIME Test ID: 2024-04-28-6-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-05-13
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Jacob Vega
Date of test: 05/01/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1794.1 g
Mass Loss: 155.2 g
Correction Factor (Percent by mass of HMA Specimen): 0.90 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.17 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.58 %
General comments (publicly viewable) (Max 1000 characters): LOT 1 SUBLOT 11
Vulcan Vallejo Drier Drum Plant
Test was verified on 5/13/2024 ✔