Summary for Test 2017-06-02-1-3
Test performed: ASTM A884-14Project Information
| Project Identifiers | Project ID: 211848 DEA: 112T2174 EFIS: 1116000131 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-5-R37.4 - R46.5 |
| Award Date | 12/22/2016 |
| Closeout Date | Not set |
| Work Description | (Alternative Delivery) CMGC, San Elijo Highway Bridge Replacement. Replace the San Elijo lagoon highway bridge, construct HOV lanes, construct bike and pedestrian trails and bridge, build multi-use facility at Manchester Ave. |
| Location Description | IN SAN DIEGO COUNTY IN SOLANA BEACH AND ENCINITAS FROM 0.1 MILE NORTH OF LOMAS SANTA FE DRIVE OVERCROSSING TO 0.2 MILE SOUTH OF BIRMINGHAM DRIVE OVERCROSSING |
| QA Service Level | 1 (Verified on 01/31/2017) |
Sample Information
| Sample Taken Date | 06/02/2017 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/07/2017 |
| Sample type | Quality Assurance | A brief description of the sample | Epoxy Coated Rebar with Nuts |
| The quantity of what the sample constitutes | 2 bars and 2 Hex nuts | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Subramony | Last name of sampler or witnessed by | Krishnamoorthy |
| Title of sampler | QAI | Telephone number of sampler | 951-436-6777 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Williams Forms | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L88-004-17 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 75 |
| Threaded Bar Type | Rebar Size | #8 | |
| Nut Specification for Threaded Bar | ASTM A108 | System Manufacturer | Williams Form Eng |
| Epoxy Coating Color | Purple | Threaded Bar Application | Soil Nail |
| Coating Standards | ASTM A934 epoxy | Bar Heat Number(s) | 100787824 |
| Nut Heat Number(s) | NF15202140 | Bar Lot Number | 10078782420 |
| Nut Lot Number | NF1520214052 | Coupler Heat Number(s) | Unknown |
| Coupler Grade | 1215G2 |
Test Details
DIME Sample ID: 2017-06-02-1
DIME Test ID: 2017-06-02-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A884-14: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Epoxy Coating Thickness)
Test Release Date: 2017-06-15
Test Results
Input Type: Measured
Tester's full name: Glen Weldon
Date of test: 06/07/2017
Lower spec. limit LSL: 10 mils
Upper spec. limit USL: 15 mils
First Bar Side 1 mean value: 12.94 mils
First Bar Side 2 mean value: 13.64 mils
Second Bar Side 1 mean value: 12.58 mils
Second Bar Side 2 mean value: 12.6 mils
First Bar Mean: 13.29 mils
Second Bar Mean: 12.59 mils
Total mean value: 12.94 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/8/2017 ✔