Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2017-06-02-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211848
DEA: 112T2174
EFIS: 1116000131
DIST-CO-RTE-PM11-SD-5-R37.4 - R46.5
Award Date12/22/2016
Closeout DateNot set
Work Description(Alternative Delivery) CMGC, San Elijo Highway Bridge Replacement. Replace the San Elijo lagoon highway bridge, construct HOV lanes, construct bike and pedestrian trails and bridge, build multi-use facility at Manchester Ave.
Location DescriptionIN SAN DIEGO COUNTY IN SOLANA BEACH AND ENCINITAS FROM 0.1 MILE NORTH OF LOMAS SANTA FE DRIVE OVERCROSSING TO 0.2 MILE SOUTH OF BIRMINGHAM DRIVE OVERCROSSING
QA Service Level1 (Verified on 01/31/2017)

Sample Information

Sample Taken Date06/02/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/07/2017
Sample typeQuality Assurance A brief description of the sampleEpoxy Coated Rebar with Nuts
The quantity of what the sample constitutes2 bars and 2 Hex nuts From where was the sample collectedFabricator
First name of sampler or witnessed bySubramony Last name of sampler or witnessed byKrishnamoorthy
Title of samplerQAI Telephone number of sampler951-436-6777
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameWilliams Forms Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormL88-004-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingProduction Testing
Threaded Bar SpecificationASTM A615 Threaded Bar Grade75
Threaded Bar Type Rebar Size#8
Nut Specification for Threaded BarASTM A108 System ManufacturerWilliams Form Eng
Epoxy Coating ColorPurple Threaded Bar ApplicationSoil Nail
Coating StandardsASTM A934 epoxy Bar Heat Number(s)100787824
Nut Heat Number(s)NF15202140 Bar Lot Number10078782420
Nut Lot NumberNF1520214052 Coupler Heat Number(s)Unknown
Coupler Grade1215G2

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-06-02-1-1ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory06/07/2017Fred
Yes
06/15/2017A615 Bar & Nut
2017-06-02-1-2ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory06/07/2017Fred
Yes
06/15/2017A615 Bar & Nut
2017-06-02-1-3ASTM A884-14: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Epoxy Coating Thickness)Glen Weldon, CT HQ - Sacramento Structural Materials Testing Laboratory06/07/2017Glen Weldon
Yes
06/15/2017

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-06-02-1-1 ASTM A615-15 (Verified)
DIME Test ID: 2017-06-02-1-2 ASTM A615-15 (Verified)